COMMSCOPE NetConnect CAT6 U/UTP Cable Grey-305m | 1000 Feet-884036314/10
Category 6 U/UTP Cable, low smoke zero halogen, gray jacket, 4 pair count, 1000 ft (305 m) length Commpak
Category : Copper
Brand : Commscope
Model : 884036314/10 | CS37Z3 GRY
Description
Product Classification
- Regional Availability : Asia
- Portfolio : NETCONNECT®
- Product Type : Twisted pair cable
- Ordering Note : Available in Asia Pacific
General Specifications
- Product Number : CS37Z3
- ANSI/TIA Category : 6
- Cable Component Type : Horizontal
- Cable Type : U/UTP (unshielded)
- Conductor Type, singles : Solid
- Conductors, quantity : 8
- Jacket Color : Gray
- Note : All electrical transmission tests include swept frequency measurements | Testing Frequency up to 600 MHz
- Pairs, quantity : 4
- Separator Type : Isolator
- Transmission Standards : ANSI/TIA-568.2-D | CENELEC EN 50288-6-1 | ISO/IEC 11801 Class E
Dimensions
- Cable Length : 304.8 m | 1000 ft
- Diameter Over Conductor : 1.039 mm | 0.0409 in
- Diameter Over Jacket, nominal : 5.842 mm | 0.23 in
- Jacket Thickness : 0.559 mm | 0.022 in
- Conductor Gauge, singles : 23 AWG
Electrical Specifications
- Characteristic Impedance : 100 ohm
- dc Resistance Unbalance, maximum : 5 %
- dc Resistance, maximum : 7.61 ohms/100 m | 2.32 ohms/100 ft
- Delay Skew, maximum : 45 ns
- Dielectric Strength, minimum : 1500 Vac | 2500 Vdc
- Mutual Capacitance at Frequency : 5.6 nF/100 m @ 1 kHz
- Nominal Velocity of Propagation (NVP) : 68 %
- Operating Frequency, maximum : 400 MHz
- Operating Voltage, maximum : 80 V
- Remote Powering : Fully complies with the recommendations set forth by IEEE 802.3bt (Type 4) for the safe delivery of power over LAN cable when installed according to ISO/IEC 14763-2, CENELEC EN 50174-1, CENELEC EN 50174-2 or TIA TSB-184-A
- Safety Voltage Rating : 300 V
Electrical Cable Performance
- CS : CommScope
- Std : Refers to the standard value listed under Transmission Standards in the Electrical Specifications above
- Typ : Typical
- IL : Insertion Loss (dB/100m)
- NEXT : Near End Crosstalk (dB/100m)
- ACR : Attenuation to Crosstalk Ratio (dB/100m))
- PSNEXT : Power Sum Near End Crosstalk (db/100m)
- PSACR : Power Sum Attenuation to Crosstalk Ratio (dB/100m)
- ACRF : Attenuation to Crosstalk Ratio - Far End (dB/100m)
- PSACRF : Insertion Loss (dB/100m)
- RL : Return Loss (dB)
Material Specifications
- Conductor Material : Bare copper
- Insulation Material : Polyolefin
- Jacket Material : Low Smoke Zero Halogen (LSZH)
- Separator Material : Polyolefin
Mechanical Specifications
- Pulling Tension, maximum : 11.34 kg | 25 lb
Environmental Specifications
- Installation temperature : 0 °C to +60 °C (+32 °F to +140 °F)
- Operating Temperature : -20 °C to +60 °C (-4 °F to +140 °F)
- Acid Gas Test Method : IEC 60754-2
- Environmental Space : Low Smoke Zero Halogen (LSZH)
- Flame Test Method : IEC 60332-3-22
- Smoke Test Method : IEC 61034-2
Packaging and Weights
- Cable weight : 37.249 kg/km | 25.03 lb/kft
- Packaging Type : CommPak® box
Regulatory Compliance/Certifications
- ISO 9001:2015 : Designed, manufactured and/or distributed under this quality management system
- ROHS : Compliant
- CHINA-ROHS : Below maximum concentration value
- REACH-SVHC : Compliant as per SVHC revision on www.commscope.com/ProductCompliance