Category 6 U/UTP Cable, low smoke zero halogen, gray jacket, 4 pair count, 1000 ft (305 m) length Commpak

Category : Copper
Brand : Commscope
Model : 884036314/10 | CS37Z3 GRY

Description

Product Classification

  • Regional Availability : Asia
  • Portfolio : NETCONNECT®
  • Product Type : Twisted pair cable
  • Ordering Note : Available in Asia Pacific

General Specifications

  • Product Number : CS37Z3
  • ANSI/TIA Category : 6
  • Cable Component Type : Horizontal
  • Cable Type : U/UTP (unshielded)
  • Conductor Type, singles : Solid
  • Conductors, quantity : 8
  • Jacket Color : Gray
  • Note : All electrical transmission tests include swept frequency measurements | Testing Frequency up to 600 MHz
  • Pairs, quantity : 4
  • Separator Type : Isolator
  • Transmission Standards : ANSI/TIA-568.2-D | CENELEC EN 50288-6-1 | ISO/IEC 11801 Class E

Dimensions

  • Cable Length : 304.8 m | 1000 ft
  • Diameter Over Conductor : 1.039 mm | 0.0409 in
  • Diameter Over Jacket, nominal : 5.842 mm | 0.23 in
  • Jacket Thickness : 0.559 mm | 0.022 in
  • Conductor Gauge, singles : 23 AWG

Electrical Specifications

  • Characteristic Impedance : 100 ohm
  • dc Resistance Unbalance, maximum : 5 %
  • dc Resistance, maximum : 7.61 ohms/100 m | 2.32 ohms/100 ft
  • Delay Skew, maximum : 45 ns
  • Dielectric Strength, minimum : 1500 Vac | 2500 Vdc
  • Mutual Capacitance at Frequency : 5.6 nF/100 m @ 1 kHz
  • Nominal Velocity of Propagation (NVP) : 68 %
  • Operating Frequency, maximum : 400 MHz
  • Operating Voltage, maximum : 80 V
  • Remote Powering : Fully complies with the recommendations set forth by IEEE 802.3bt (Type 4) for the safe delivery of power over LAN cable when installed according to ISO/IEC 14763-2, CENELEC EN 50174-1, CENELEC EN 50174-2 or TIA TSB-184-A
  • Safety Voltage Rating : 300 V

Electrical Cable Performance

  • CS : CommScope
  • Std : Refers to the standard value listed under Transmission Standards in the Electrical Specifications above
  • Typ : Typical
  • IL : Insertion Loss (dB/100m)
  • NEXT : Near End Crosstalk (dB/100m)
  • ACR : Attenuation to Crosstalk Ratio (dB/100m))
  • PSNEXT : Power Sum Near End Crosstalk (db/100m)
  • PSACR : Power Sum Attenuation to Crosstalk Ratio (dB/100m)
  • ACRF : Attenuation to Crosstalk Ratio - Far End (dB/100m)
  • PSACRF : Insertion Loss (dB/100m)
  • RL : Return Loss (dB)

Material Specifications

  • Conductor Material : Bare copper
  • Insulation Material : Polyolefin
  • Jacket Material : Low Smoke Zero Halogen (LSZH)
  • Separator Material : Polyolefin

Mechanical Specifications

  • Pulling Tension, maximum : 11.34 kg | 25 lb

Environmental Specifications

  • Installation temperature : 0 °C to +60 °C (+32 °F to +140 °F)
  • Operating Temperature : -20 °C to +60 °C (-4 °F to +140 °F)
  • Acid Gas Test Method : IEC 60754-2
  • Environmental Space : Low Smoke Zero Halogen (LSZH)
  • Flame Test Method : IEC 60332-3-22
  • Smoke Test Method : IEC 61034-2

Packaging and Weights

  • Cable weight : 37.249 kg/km | 25.03 lb/kft
  • Packaging Type : CommPak® box

Regulatory Compliance/Certifications

  • ISO 9001:2015  : Designed, manufactured and/or distributed under this quality management system
  • ROHS : Compliant
  • CHINA-ROHS  : Below maximum concentration value
  • REACH-SVHC : Compliant as per SVHC revision on www.commscope.com/ProductCompliance